Oil heat is still common in older homes, especially across the Northeast and parts of the Midwest, and it needs techs who know oil burners. When your oil furnace stops firing or starts smoking, we connect you with a local heating company in Springbrook, WI that services and repairs oil-fired equipment.
How an oil furnace fails
An oil burner pumps fuel through a fine nozzle, sprays it as a mist, and lights it with a spark from the electrodes. A cad cell, a small light-sensing eye, confirms there is a flame. If the cad cell doesn't see fire within a few seconds, the primary control locks the burner out. That red reset button on the burner is the control telling you it shut down for a reason.
- Out of oil, or a tank gauge that reads wrong
- Clogged oil filter or nozzle, often from sludge at the bottom of the tank
- Dirty cad cell or misaligned electrodes
- Failing fuel pump or burner motor
- Air in the oil line after running out of fuel
- Blocked chimney or flue
Don't keep pressing reset
Each press of the reset button can send more oil into the combustion chamber. If it doesn't light, that unburned oil sits there. Press it again and you risk a puffback, a small explosion that can blow soot through the house. Press it once at most. If it doesn't fire, call.
What the tech checks
Expect a look at the tank level, filter and line, then the burner: nozzle, electrodes, cad cell, pump pressure and the transformer or igniter. A combustion test checks smoke number, draft and efficiency. The tech should also look at the chimney base and barometric damper. Most oil service visits replace the nozzle and filter as routine, which is why oil systems benefit from yearly furnace maintenance.
What drives the cost
A nozzle and filter change is routine work. A fuel pump, burner motor or primary control costs more. A puffback cleanup, a tank issue or chimney work adds up quickly. Bleeding air from the lines after running dry takes time on its own.
Oil boilers and conversions
Many oil homes heat with a boiler instead of a furnace; the burner is similar, but the water side of a boiler is its own specialty. If your oil furnace is very old and you have natural gas at the street, some homeowners look at replacing the system with a gas unit.
Smoke or soot
Black soot around registers, a burnt oil smell or smoke from the burner means shut the system off and call. If a CO alarm sounds, get out and call 911. A yearly safety inspection with a combustion test catches many of these problems early.
Call (608) 871-1284 to reach an oil heat tech who serves Springbrook, WI.